PRODUCTS & SOLUTIONS

OPGW with Stranded Stainless-Steel Tube

OPGW with Stranded Stainless-Steel Tube (Single tube, all ACS)

 

Structural Parameters Table

 

Cable Type Specification

Structure and Composition

OPGW-2S1/48(M154/R96-199 )

Type

Conductivity

Diameter

No.

Remarks

Central Part

Single Wire

ACS

40%

3.4

1

 

1st Layer

Single Wire

ACS

40%

3.3

5

 

Optical Unit

Stainless-Steel Tube

/

3.2

1

 

2nd Layer

Single Wire

ACS

40%

3.3

12

 

 

Technical Data Table

 

No.

Item

Unit

Technical Date Value

1

Type

/

OPGW-2S1/48(M154/R96-199 )

2

Fiber Type

G.652/G.655

G.652

3

Fiber No.

48

4

Diameter

mm

16.6

5

Bearing Cross-Section

mm2

154.48

6

Mass Per Unit Length

kg/km

747

7

RTS

kN

95.9

8

20℃ DC Resistance

Ω/km

0.284

9

Short-Circuit Current Capacity (40℃~200℃, 1s)

kA2.s

199.33

10

Draw-Weight Ratio

km

13.1

 

Structure Design

 

 

Applications:

Commonly used in newly built overhead power lines.

Can meet the requirements of big number of fibers and ultra high voltage(UHV) transmission lines.

Can provide protection against lightning by transmitting large fault short-circuit current. 

 

Main Features:

Stable structure, high reliability.

Able to obtain the second optical fiber excess-length.

Excellent resistance to distortion and side pressure.

Can withstand high mechanical stress, and easy to obtain a large short-circuit current capacity.

 

Applicable Voltage Range:

Power lines with voltage level of 110KV and below. 

Home    Transmission    OPGW    OPGW with Stranded Stainless-Steel Tube