OPGW with Stranded Stainless-Steel Tube
OPGW with Stranded Stainless-Steel Tube (Single tube, all ACS)
Structural Parameters Table
Cable Type Specification |
Structure and Composition |
|||||
OPGW-2S1/48(M154/R96-199 ) |
Type |
Conductivity |
Diameter |
No. |
Remarks |
|
Central Part |
Single Wire |
ACS |
40% |
3.4 |
1 |
|
1st Layer |
Single Wire |
ACS |
40% |
3.3 |
5 |
|
Optical Unit |
Stainless-Steel Tube |
/ |
3.2 |
1 |
|
|
2nd Layer |
Single Wire |
ACS |
40% |
3.3 |
12 |
|
Technical Data Table
No. |
Item |
Unit |
Technical Date Value |
1 |
Type |
/ |
OPGW-2S1/48(M154/R96-199 ) |
2 |
Fiber Type |
G.652/G.655 |
G.652 |
3 |
Fiber No. |
芯 |
48 |
4 |
Diameter |
mm |
16.6 |
5 |
Bearing Cross-Section |
mm2 |
154.48 |
6 |
Mass Per Unit Length |
kg/km |
747 |
7 |
RTS |
kN |
95.9 |
8 |
20℃ DC Resistance |
Ω/km |
0.284 |
9 |
Short-Circuit Current Capacity (40℃~200℃, 1s) |
kA2.s |
199.33 |
10 |
Draw-Weight Ratio |
km |
13.1 |
Structure Design
Applications:
Commonly used in newly built overhead power lines.
Can meet the requirements of big number of fibers and ultra high voltage(UHV) transmission lines.
Can provide protection against lightning by transmitting large fault short-circuit current.
Main Features:
Stable structure, high reliability.
Able to obtain the second optical fiber excess-length.
Excellent resistance to distortion and side pressure.
Can withstand high mechanical stress, and easy to obtain a large short-circuit current capacity.
Applicable Voltage Range:
Power lines with voltage level of 110KV and below.